User Tools

Site Tools


generation_of_tip_e_str.inp_files_for_stm_simulation

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
generation_of_tip_e_str.inp_files_for_stm_simulation [2010/09/02 11:14]
cegonzal created
generation_of_tip_e_str.inp_files_for_stm_simulation [2011/02/18 13:13] (current)
Line 13: Line 13:
  
        ​1.00000 ​             ! ratio of lattice (for fractional coordinates,​ if xyz are in Angstroms maintain 1.000)        ​1.00000 ​             ! ratio of lattice (for fractional coordinates,​ if xyz are in Angstroms maintain 1.000)
-       ​1 ​  60               ! natom_beg,​natom_end (initial and final atom for the DOS calculation) ​    151                    ! number of energies (number of energies in the DOS calcuation) +       ​1 ​  5                ​! natom_beg,​natom_end (initial and final atom for the DOS calculation) ​   
-  -10.749617402457092 ​0.10  ​! first energy (initial absolute energy (fireball'​s value is the Fermi Level) and energy step   +     ​401                    ! number of energies (number of energies in the DOS calcuation) 
-                          ! 1/0 yes/no write the tip_e_str.inp file for the DOS +  -12.0    ​0.05             ! first energy (initial absolute energy (fireball'​s value is the Fermi Level) and energy step   
-      -4.00  4.00           ! minimun and maximum energy limit for writing the green function in the tip_e_str.inp file+                          ! 1/0 yes/no write the tip_e_str.inp file for the DOS 
 +      -4.01  4.01           ! minimun and maximum energy limit for writing the green function in the tip_e_str.inp file
        ​0.05 ​                ! imaginary part for the green function in the DOS calculation        ​0.05 ​                ! imaginary part for the green function in the DOS calculation
  
 ---- ----
  
 +One comment related with the minimum and maximum energy limits. Normally, we are interested in the range 2eV bellow and above the Fermi Level, but calculating a bigger range of DOS. These parameters give us the opportunity to do both things together: dos calculation and tip_e_str.inp fie generation. As an example we can consider a system with a FL=-2.0 eV and we want to generate the file from -2+FL to FL+2 doing the calculation of the complete DOS from -10 to +10 with an energy step of 0.05. The corresponding file is showed above. (Take a look to the minimum and maximum vales a little bit larger to avoid numerical bad effects). 
 +  ​
generation_of_tip_e_str.inp_files_for_stm_simulation.txt · Last modified: 2011/02/18 13:13 (external edit)