linear_stm [2009/11/30 11:23]
vroz
linear_stm [2009/11/30 12:23]
vroz
Line 7: Line 7:
 === options.inp ===    === options.inp ===   
  
-Here the settings is same ([])+Here the settings is same ([The files]), just the **ICUTT** parameter we have to change to value 1. Than the scan will be linear. Other values can stay same. 
 + 
 +\\ 
 + 
 +=== scan.inp === 
 + 
 +In the case of linear scan, the initial and final point should be changed maybe. But the **XMIN XMAX** or the **YMIN YMAX** will be same there.  
 + 
 + \\ 
 + 
 +==== ==== 
 + 
 +Than, you can run the **STM** code for linear scan simulation. 
 + 
 + \\ 
 + 
 +=== Output ===  
 + 
 +As an output, we will obtain the "​scan_cut_deno.out"​ or "​scan_cut_nden.out"​ file, depends on the settings (the denominator means the multiple scattering is involved and the *nden.out file is obtained). The file has the following format (there is 50 rows, the scan is from the point (0.0,0.0) to (0.0,​4.1742) for the distance 3A): 
 + 
 +0.000000 ​   0.000000 ​   0.000000 ​   3.000000 ​ 0.14821E-05 \\ 
 +0.083484 ​   0.000000 ​   0.083484 ​   3.000000 ​ 0.14866E-05 \\ 
 +. \\ 
 +. \\ 
 +. \\ 
 +4.174200 ​   0.000000 ​   4.174200 ​   3.000000 ​ 0.14821E-05 
 + 
 +The first column gives us the length of path of the tip over the surface from the initial point, columns 2 and 3 are the x and y coordinate of the tip, 4. is the distance between tip apex and the surface and 5. column gives us the current at the given xy position.
linear_stm.txt · Last modified: 2011/02/18 13:13 (external edit)