User Tools

Site Tools


probe_particle_stm

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
probe_particle_stm [2018/10/24 12:22]
krejcio [Literature]
probe_particle_stm [2021/11/16 20:59] (current)
krejcio
Line 1: Line 1:
 +===== !!! Outdated !!! =====
 +
 +The repository changed to [[https://​github.com/​Probe-Particle/​PPSTM]] and all the documentation is copied and updated in its new Wiki [[https://​github.com/​Probe-Particle/​PPSTM/​wiki]].
 +
 +What is here is the left-over of the original documentation.
 +
 ===== Introduction ===== ===== Introduction =====
  
Line 13: Line 19:
 The PP-STM code calculates an STM or dI/dV signal based on the input from various Linear Combination of Atomic Orbitals (LCAO)-DFT codes. These inputs are eigen-energies of eigen-states (molecular orbitals) and LCAO coefficients (for each state and atomic orbital of sample). Sample can be approximated by freestanding molecule, or by full system - molecule/​substrate. The PP-STM code calculates an STM or dI/dV signal based on the input from various Linear Combination of Atomic Orbitals (LCAO)-DFT codes. These inputs are eigen-energies of eigen-states (molecular orbitals) and LCAO coefficients (for each state and atomic orbital of sample). Sample can be approximated by freestanding molecule, or by full system - molecule/​substrate.
  
-Nowadays these LCAO DFT codes can be used for the creation of necessary PP-STM inputs: //​Fireball//​ [[http://​sites.google.com/​site/​fireballofficialsite/​]],​ //​FHI-AIMS//​ [[http://​aimsclub.fhi-berlin.mpg.de]] and //GPAW// in the LCAO mode [[http://​wiki.fysik.dtu.dk/​gpaw/​documentation/​lcao/​lcao.html]]+Nowadays these LCAO DFT codes can be used for the creation of necessary PP-STM inputs: //​Fireball//​ [[http://​sites.google.com/​site/​fireballofficialsite/​]],​ //​FHI-AIMS//​ [[http://​aimsclub.fhi-berlin.mpg.de]], //CP2K// [[https://​www.cp2k.org/​]] and //GPAW// in the LCAO mode [[http://​wiki.fysik.dtu.dk/​gpaw/​documentation/​lcao/​lcao.html]]
  
 Detailed description of the PP-STM code principle is shown in PRB 95, 045407 (2017) - see the literature. Detailed description of the PP-STM code principle is shown in PRB 95, 045407 (2017) - see the literature.
Line 69: Line 75:
    
  - Example of PPSTM simulations with flexible CO tip: [[4N-coronene]]  - Example of PPSTM simulations with flexible CO tip: [[4N-coronene]]
 +
 +
 + - Example of PP-IETS simulation with flexible CO tip: [[FePc_Au]]
  
  
probe_particle_stm.1540376533.txt.gz ยท Last modified: 2018/10/24 12:22 by krejcio